p1151[0...n]
Ramp-function generator configuration / RFG config
SERVO_S110-CAN
Can be changed: U, T
(Extended set),
Data type: Unsigned16
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-
Description:
Sets the configuration for the extended ramp-function generator.
Bit field:
Bit
Signal name
00
Disable rounding-off at the zero cross-over
Caution:
Re bit 00 = 1:
If the ramp-up time is longer than the ramp-down time (p1120 > p1121), then there is an acceleration step at the
zero crossover. This can have a negative impact on the mechanical system.
Note:
Re bit 00 = 1:
When the direction change is changed there is no rounding-off before and after the zero crossover.
p1152
BI: Setpoint 2 enable / Setp 2 enab
SERVO_S110-CAN
Can be changed: T
(Extended brk),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Commands
(Extended brk),
Not for motor type: -
SERVO_S110-PN
(Extended brk)
Min
-
Description:
Sets the signal source for "setpoint 2 enable".
p1155[0...n]
CI: Speed controller speed setpoint 1 / n_ctrl n_set 1
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-PN
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for speed setpoint 1 of the speed controller.
Dependency:
The effectiveness of this setpoint depends on, e.g. STW1.4 and STW1.6.
Refer to: r0002, p0840, p0844, p0848, p0852, p0854, r0898, p1140, p1142, p1160, r1170, p1189, p1414, p1417,
p1418
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1160[0...n]
CI: Speed controller speed setpoint 2 / n_ctrl n_set 2
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-PN
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for speed setpoint 2 of the speed controller.
Dependency:
Refer to: p1155, r1170
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: p2000
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: p2000
Max
-
Parameter
List of parameters
Access level: 2
Func. diagram: 3070
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
FP
No
3070
Access level: 3
Func. diagram: 2711, 4015
Unit selection: -
Expert list: 1
Factory setting
899.15
Access level: 3
Func. diagram: 1550, 3080,
5030, 6031
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 1550, 3080
Unit selection: -
Expert list: 1
Factory setting
0
1-211