RESET_O: 1, 2 or 3 - set direct output 1, 2 or 3 (both)
JERK: 0 - de-activate, 1 - activate
p2623[0...n]
EPOS traversing block, task mode / Trav_block mode
SERVO_S110-CAN
Can be changed: U, T
(EPOS),
Data type: Unsigned16
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
0
Description:
Sets the influence of the task for the traversing block.
Value = 0000 cccc bbbb aaaa
cccc: Positioning mode
cccc = 0000 --> ABSOLUTE
cccc = 0001 --> RELATIVE
cccc = 0010 --> ABS_POS (only for a rotary axis with modulo correction)
cccc = 0011 --> ABS_NEG (only for a rotary axis with modulo correction)
bbbb: Progression condition
bbbb = 0000 --> END
bbbb = 0001 --> CONTINUE WITH STOP
bbbb = 0010 --> CONTINUE FLYING
bbbb = 0011 --> CONTINUE EXTERNAL
bbbb = 0100 --> CONTINUE EXTERNAL WAIT
bbbb = 0101 --> CONTINUE EXTERNAL ALARM
aaaa: IDs
aaaa = 000x --> show/hide block (x = 0: show, x = 1: hide)
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2624
p2624
EPOS traversing block, sorting / Trav_block sort
SERVO_S110-CAN
Can be changed: U, T
(EPOS),
Data type: Unsigned16
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
0
Description:
Sets the traversing blocks for sorting corresponding to their block number.
Procedure: Set p2624 = 0 --> 1.
Sorting is started and the parameters are automatically reset to zero once the operation has been completed.
Dependency:
Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623
Note:
After sorting, the traversing blocks are written at the beginning of the memory in increasing sequence without any
gaps.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: p2615
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Parameter
List of parameters
Access level: 1
Func. diagram: 3515, 3616
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 3616
Unit selection: -
Expert list: 1
Factory setting
0
1-393