Siemens SINAMICS S110 List Manual page 110

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p0449[0...n]
Encoder SSI number of bits, filler bits / Enc SSI fill bits
SERVO_S110-CAN,
Can be changed: C2(4)
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the number of filler bits for double absolute value transfer in the SSI protocol.
Dependency:
Refer to: p0429
Caution:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
This parameter is only of significance for p0429.2 = 1.
r0451[0...2]
Commutation angle factor / Enc commut_factor
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the relationship between the electrical and mechanical pole positions.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Note:
A value of zero is displayed if an encoder is not present.
r0452[0...2]
Squarewave encoder filter time display / Enc t_filt displ
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
- [µs]
Description:
Displays the effective filter time for a squarewave encoder.
The filter time is set using p0438.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p0438
Note:
A value of zero is displayed if an encoder is not present.
p0453[0...n]
Pulse encoder evaluation zero speed measuring time / Enc_ev z 0 t_meas
SERVO_S110-CAN,
Can be changed: C2(4)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0.10 [ms]
Description:
Sets the measuring time for evaluating zero speed.
If no pulses are detected from track A/B during this time, a speed actual value of zero is output.
Dependency:
Refer to: r0452
1-110
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [µs]
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
10000.00 [ms]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 4710
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [µs]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1000.00 [ms]

Hide quick links: