Parameter
List of parameters
p3088
MotId Motor model changeover speed operation with encoder ident. /
MotMod n_chgSnsorl
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
0.00000 [rpm]
Description:
Changeover speed for the motor model with encoder determined by the motor data identification.
This changeover speed can be changed after the identification and accepted in p1752 with p1910/p1960 = -3.
Dependency:
Refer to: p1752, p1910
p3100
RTC time stamp mode / RTC t_stamp mode
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the mode for the time stamp
p3100 = 0: Time stamp, operating hours
p3100 = 1: Time stamp, UTC format
Note:
RTC: Real-time clock
UTC: Universal Time Coordinates
The UTC time started, according to the definition on 01.01.1970 at 00:00:00 and is output in days and milliseconds.
p3101[0...1]
RTC set UTC time / RTC set UTC
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Setting the UTC time.
This means that the drive system is synchronized to the time specified by the time master. To start p3101[1] must
be written to followed by p3101[0]. After writing to p3101[0], the UTC time is accepted.
p3101[0]: Milliseconds
p3101[1]: Days
r3102[0...1]
RTC read UTC time / RTC read UTC
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the current UTC time in the drive system.
p3102[0]: Milliseconds
p3102[1]: Days
1-426
Calculated: CALC_MOD_ALL
Dynamic index: -
Units group: -
Scaling: -
Max
210000.00000 [rpm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
4294967295
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00000 [rpm]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-

Hide quick links: