Parameter values
Min
Max
Factory setting
Not for motor type
Specifies for which motor type this parameter has no significance
ASM: Induction motor
FEM: Separately excited synchronous motor
PEM: Permanent-magnet synchronous motor
REL: Reluctance motor/SIEMOSYN motor
Scaling
Specification of the reference variable with which a signal value is automatically
converted for a BICO interconnection.
The following reference variables are available:
• p2000 ... p2007: Reference speed, reference voltage, etc.
• PERCENT: 1.0 = 100 %
• 4000H: 4000 hex = 100 %
Expert list
Specifies whether this parameter is available in the expert list of the specified
drive objects in the commissioning software.
1: Parameter does exist in the expert list.
0: Parameter does not exist in the expert list.
Notice:
Users are responsible for using parameters that are marked "Expert list: 0"
(parameter not included in the expert list).
These parameters and their functionalities have not been tested and no further
user documentation is available for them (e.g. description of functions). Moreover,
no support is provided for these parameters by "Technical Support" (hotline).
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Minimum value of the parameter [unit]
Maximum value of the parameter [unit]
Value when shipped [unit]
A different value may be displayed for certain parameters
(e.g.p1800) at the initial commissioning stage.
Reason:
The setting of these parameters is determined by the
operating environment of the Control Unit (e.g.depending
on converter type, macro, power unit).
Parameter
Overview of parameters
1-23