Siemens SINAMICS S110 List Manual page 380

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p2578
CI: EPOS software limit switch minus signal source / SW limSw Min S_src
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Integer32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the software limit switch minus.
Dependency:
Refer to: p2579, p2580, p2581, p2582
Refer to: A07469, A07477, A07479, F07481
Notice:
A change to the software limit switch becomes immediately effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note:
The following applies for the setting of the software limit switch:
Software limit switch minus < software limit switch plus
p2579
CI: EPOS software limit switch plus signal source / SW limSwPlus S_src
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Integer32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the software limit switch plus.
Dependency:
Refer to: p2578, p2580, p2581, p2582
Refer to: A07470, A07478, A07480, F07482
Notice:
A change to the software limit switch becomes immediately effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note:
The following applies for the setting of the software limit switch:
Software limit switch minus < software limit switch plus
p2580
CO: EPOS software limit switch minus / SW limSwitch minus
SERVO_S110-CAN
Can be changed: U, T
(EPOS),
Data type: Integer32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-2147482648 [LU]
Description:
Sets the software limit switch in the negative direction of travel.
Dependency:
Refer to: p2578, p2579, p2581, p2582
p2581
CO: EPOS software limit switch plus / SW lim switch plus
SERVO_S110-CAN
Can be changed: U, T
(EPOS),
Data type: Integer32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-2147482648 [LU]
Description:
Sets the software limit switch in the positive direction of travel.
1-380
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
2147482647 [LU]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
2147482647 [LU]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: 3630
Unit selection: -
Expert list: 1
Factory setting
2580[0]
Access level: 1
Func. diagram: 3630
Unit selection: -
Expert list: 1
Factory setting
2581[0]
Access level: 1
Func. diagram: 3630
Unit selection: -
Expert list: 1
Factory setting
-2147482648 [LU]
Access level: 1
Func. diagram: 3630
Unit selection: -
Expert list: 1
Factory setting
2147482647 [LU]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents