Parameter
List of parameters
Re state "prompt to remove the armature short-circuit" (r1238 = 5):
- the activation criterion is no longer fulfilled. An attempt is made to again remove the armature short circuit.
- the control signal to close the contactor r1239.0 is set to "0" (open) and the pulses remain suppressed.
- if a contactor feedback signal is not connected (BI: p1235 = 0 signal), the system waits for the delay time (p1237)
to expire until a transition is made into state 1.
- if a contactor feedback signal is connected, the system waits until the feedback signal at BI:p1235 goes to "0"
(open) until a transition is made into state 1. If this does not occur within the monitoring time (p1236), then a transi-
tion is made into state 6.
Re state "active - feedback signal "Open" missing" (r1238 = 6):
- this error state can be exited by de-selecting the external armature short-circuit (p1231 = 0).
r1239.0...13
CO/BO: Armature short-circuit / DC braking status word / ASC/DCBRK ZSW
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Functions
Not for motor type: -
Min
-
Description:
Displays the status word for armature short-circuit.
Bit field:
Bit
Signal name
00
External armature short-circuit
01
External armature short-circuit, contactor
feedback signal
02
External armature short-circuit ready
03
External armature short-circuit with contac-
tor feedback signal
04
Internal armature short-circuit
05
Internal armature short circuit, feedback sig-
nal from power unit
06
Internal armature short-circuit ready
08
DC braking active
10
DC braking ready
11
Armature short circuit/DC braking selected
12
DC braking selection internally inhibited
13
DC braking for OFF1/OFF3
Dependency:
Refer to: p1230, p1231, p1232, p1233, p1234, p1235, p1236, p1237
Note:
External armature short-circuit (bits 0 ... 3):
Re bit 00:
Using this signal, the motor is short-circuited through an external contactor circuit. This means that this BO:
p1239.0 must be interconnected e.g. to a digital output.
Re bit 01:
This signal indicates the state of the contactor to establish the armature short-circuit. To do this, BI: p1235 must be
interconnected to a digital input.
Re bit 02:
The external armature short-circuit configuration is ready and is activated as soon as the activation criterion is ful-
filled.
Re bit 03:
1: A feedback signal from an external contactor was parameterized in BI: p1235.
Internal voltage protection / internal armature short-circuit (bits 4 ... 6):
Re bit 04:
a) Internal voltage protection (p1231 = 3) was selected and the Motor Module does not support the autonomous
internal voltage protection (r0192.10 = 0).
The Control Unit issues the command to the Motor Module to short-circuit the motor through the power semicon-
ductors.
a) Internal voltage protection (p1231 = 3) was selected and the Motor Module supports the autonomous internal
voltage protection (r0192.10 = 1).
1-228
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Active
Closed
Yes
Yes
Active
Active
Yes
Yes
Yes
Yes
Yes
Yes
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
Inactive
-
Open
-
No
-
No
-
Inactive
-
Inactive
-
No
-
No
7017
No
7017
No
-
No
-
No
-