Parameter
List of parameters
p1278
Brake control, diagnostics evaluation / Brake diagnostics
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Functions
Not for motor type: -
Min
0
Description:
Sets the brake control type (with or without diagnostics evaluation).
Example for brake control with diagnostics evaluation.
- brake control in the Motor Modules in booksize format
- Safe Brake Relay for AC Drive
Example for brake control without diagnostics evaluation.
- Brake Relay for AC Drive
Value:
0:
1:
Note:
If the configuration of the motor holding brake (p1215) is set to "no holding brake present" when booting, then an
automatic identification of the motor holding brake will be carried out. If a brake control is detected without diagnos-
tics evaluation (e.g. Brake Relay for AC Drive), then the parameter is set to "brake control without diagnostics eval-
uation".
It is not permissible to parameterize "brake control without diagnostics evaluation" and also enable "safe brake con-
trol" (p1278 = 1, p9602 = 1, p9802 = 1).
p1279[0...3]
BI: Motor holding brake, OR/AND logic operation / Brake OR AND
SERVO_S110-CAN
Can be changed: T
(Extended brk),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Functions
(Extended brk),
Not for motor type: -
SERVO_S110-PN
(Extended brk)
Min
-
Description:
Sets the signal source for the OR/AND logic operation.
Dependency:
Refer to: r1229
Note:
[0]: OR logic operation, input 1 --> the result is displayed in r1229.10.
[1]: OR logic operation, input 2 --> the result is displayed in r1229.10.
[2]: AND logic operation, input 1 --> the result is displayed in r1229.11.
[3]: AND logic operation, input 2 --> the result is displayed in r1229.11.
p1300[0...n]
Open-loop/closed-loop control operating mode / Op/cl-lp ctrl_mode
SERVO_S110-CAN,
Can be changed: C2(1), T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: V/f open-loop control
Not for motor type: -
Min
20
Description:
Sets the open and closed-loop control mode of a drive.
Value:
20:
21:
23:
Dependency:
Closed-loop speed or torque control (with encoder) cannot be selected if the encoder type is not entered (p0400).
Refer to: p0108, r0108, p0300, p0311, p0400, p1501
Notice:
General conditions for encoderless operation can be found in the following literature:
SINAMICS S120 Function Manual Drive Functions
1-232
Brake control with diagnostics evaluation
Brake control without diagnostics evaluation
Speed control (encoderless)
Speed control (with encoder)
Torque control (with encoder)
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
23
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2707
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 1590, 1690,
5060, 6300
Unit selection: -
Expert list: 1
Factory setting
21