Parameter
List of parameters
p2147
Delete fault buffer of all drive objects / Del fault buffer
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
0
Description:
Setting to delete the fault buffer of all existing drive objects.
Value:
0:
1:
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136
Note:
p2147 is automatically set to 0 after execution.
p2148[0...n]
BI: RFG active / RFG active
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
SERVO_S110-PN
Data type: Unsigned32 / Binary
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the signal source for the signal "ramp-function generator active" for the following signals/messages:
"Speed setpoint - actual value deviation within tolerance t_on" (BO: r2199.4)
"Ramp-up/ramp-down completed" (BO: r2199.5)
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
The binector input is automatically pre-assigned to r1199.2.
The following applies for SERVO:
The pre-assignment is only made when the function module "setpoint channel" is activated (r0108.8 = 1).
p2149[0...n]
Monitoring configuration / Monit config
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the configuration for messages and monitoring functions.
Bit field:
Bit
Signal name
00
Enable alarm A07903
01
Load monitoring only in the 1st quadrant
03
n_act > p2155 own hysteresis
15
Automatic parameterization carried out
(p0340 = 1, p3900 > 0)
Dependency:
Refer to: r2197
Refer to: A07903
Note:
Re bit 00:
Alarm A07903 is output when the bit is set with r2197.7 = 0 (n_set <> n_act).
Re bit 01:
When the bit is set, load monitoring is only carried out in the 1st quadrant as a result of the positive characteristic
parameters (p2182 ... p2190).
Re bit 03:
When the bit is set, r2197 bit 1 and bit 2 are determined via separate hystereses.
1-326
Inactive
Start to delete the fault buffer of all drive objects
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Calculated:
CALC_MOD_LIM_REF
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 4
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 8011
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 8010, 8013
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
0 signal
FP
No
8010
No
8013
No
8010
No
-