p2257
Technology controller, ramp-up time / Tec_ctrl t_ramp-up
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
0.00 [s]
Description:
Sets the ramp-up time of the technology controller.
Dependency:
Refer to: p2252, p2258
Note:
The ramp-up time is referred to 100 %.
p2258
Technology controller ramp-down time / Tec_ctrl t_ramp-dn
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
0.00 [s]
Description:
Sets the ramp-down time of the technology controller.
Dependency:
Refer to: p2252, p2257
Note:
The ramp-down time is referred to 100 %.
r2260
CO: Technology controller setpoint after ramp-function generator /
Tec_ctr set aftRFG
SERVO_S110-CAN
Can be changed: -
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
- [%]
Description:
Sets the setpoint after the ramp-function generator of the technology controller.
p2261
Technology controller setpoint filter time constant / Tec_ctrl set T
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
0.000 [s]
Description:
Sets the time constant for the setpoint filter (PT1) of the technology controller.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
650.00 [s]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
650.00 [s]
Calculated: -
Dynamic index: -
Units group: 9_1
Scaling: PERCENT
Max
- [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
60.000 [s]
Parameter
List of parameters
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
1.00 [s]
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
1.00 [s]
Access level: 2
Func. diagram: 7958
Unit selection: p0595
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
0.000 [s]