r2134[0...63]
Alarm value for float values / Alarm value float
All objects
Can be changed: -
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays additional information about the active alarm for float values.
Dependency:
Refer to: r2110, r2122, r2123, r2124, r2125, r2145, r2146, r3121, r3123
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2135.0...15
CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the second status word of faults and alarms.
Bit field:
Bit
Signal name
00
Fault encoder 1
01
Fault encoder 2
12
Fault motor overtemperature
13
Fault power unit thermal overload
14
Alarm motor overtemperature
15
Alarm power unit thermal overload
r2136[0...63]
Fault time removed in days / t_flt resolv. days
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the system runtime in days when the fault was removed.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2114, r2130, r2133, r3115, r3120, r3122
Notice:
The time comprises r2136 (days) and r2109 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2138.7...15
CO/BO: Control word faults/alarms / STW fault/alarm
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the control word of the faults and alarms.
Bit field:
Bit
Signal name
07
Acknowledge fault
10
External alarm 1 (A07850) effective
11
External alarm 2 (A07851) effective
12
External alarm 3 (A07852) effective
13
External fault 1 (F07860) effective
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Parameter
List of parameters
Access level: 3
Func. diagram: 8065
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 1530, 2548
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
Access level: 3
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 1530, 2546
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
1-323

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents