Siemens SINAMICS S110 List Manual page 447

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Dependency:
Refer to: p4681, p4682, p4683, p4684
Note:
The display can only be reset to zero.
r4689[0...2]
CO: Squarewave encoder, diagnostics / Sq-wave enc diag
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the encoder status according to PROFIdrive for a squarewave encoder.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: A31422
Note:
After alarm A3x422 is output, this parameter is set for 100 ms.
p4690
SMI spare part component number / SMI comp_no
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
0
Description:
Sets the component number for the SMI/DQI for which motor and/or encoder data should be saved, deleted or
downloaded.
Dependency:
Refer to: p4691, p4692, p4693
Note:
DQI: DRIVE-CLiQ Sensor Integrated
SMI: SINAMICS Sensor Module Integrated
p4691
SMI spare part save/download data / Save/DL SMI data
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
0
Description:
Setting to save/download the data for the Sensor Module Integrated (SMI) specified in p4690.
Procedure:
p4690 = set component number
p4691 = 1, 2, 3, 30 set the required procedure (save/download/delete)
p4691 = 9, 10, 36 automatic on successful completion of the procedure
p4691 = 11... 22, 37, 38 --> error values if the procedure could not be executed
Value:
0:
1:
2:
3:
9:
10:
11:
12:
13:
14:
15:
16:
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Inactive
Save SMI data
Download SMI data
Download SMI data from memory card
SMI data downloaded and POWER ON required for component
SMI data backup complete
SMI data backup for selected component not found
Selected component not available or not connected
Insufficient memory space for backup
Format of saved data is incompatible
Transfer fault during data download
Transfer fault during data backup
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
399
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
38
Parameter
List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
1-447