r9749[0...63]
SI message value / SI msg_value
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Integer32
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the additional information about the safety message that occurred (as integer number).
Dependency:
Refer to: r9744, r9747, r9748, p9752, r9753, r9754, r9755, r9756
r9750[0...63]
SI diagnostic attributes / SI diag_attr
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the diagnostic attributes of the safety messages that have occurred.
Bit field:
Bit
Signal name
00
Hardware replacement recommended
p9752
SI message cases, counter / SI msg_cases count
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
0
Description:
Number of safety messages that have occurred since the last reset.
Dependency:
The safety message buffer is cleared by resetting the parameter to 0.
Refer to: r9744, r9747, r9748, r9749, r9753, r9754, r9755, r9756
Note:
The parameter is reset to 0 at POWER ON.
r9753[0...63]
SI message value for float values / SI msg_val float
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays additional information about the safety message that has occurred for float values.
Dependency:
Refer to: r9744, r9747, r9748, r9749, p9752, r9754, r9755, r9756
r9754[0...63]
SI message time received in days / SI t_msg recv days
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the relative system runtime in days when the safety message occurred.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
1-599

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents