Parameter
List of parameters
Note:
Permissible PROFIBUS addresses: 1 ... 126
Address 126 is used for commissioning.
Every PROFIBUS address change only becomes effective after a POWER ON.
p0922
IF1 PROFIdrive telegram selection / IF1 PD Telegr_sel
CU_S110-DP,
Can be changed: C2(1), T
CU_S110-PN
Data type: Unsigned16
P-Group: Communications
Not for motor type: -
Min
390
Description:
Sets the send and receive telegram.
Value:
390:
391:
392:
393:
394:
999:
p0922
IF1 PROFIdrive telegram selection / IF1 PD Telegr_sel
SERVO_S110-DP,
Can be changed: C2(1), T
SERVO_S110-PN
Data type: Unsigned16
P-Group: Communications
Not for motor type: -
Min
1
Description:
Sets the send and receive telegram.
Value:
1:
2:
3:
4:
102:
103:
999:
Dependency:
Refer to: p2038
Refer to: F01505, F01506
Note:
For p0922 = 100 ... 199, p2038 is automatically set to 1 and p2038 can no longer be changed. This means that for
these telegrams, the "SIMODRIVE 611 universal" interface mode is set and cannot be changed.
If a value is not equal to 999, a telegram is set and the automatically set interconnections in the telegram are inhib-
ited.
The inhibited interconnections can only be changed again after setting value 999.
p0922
IF1 PROFIdrive telegram selection / IF1 PD Telegr_sel
SERVO_S110-DP
Can be changed: C2(1), T
(EPOS, Pos ctrl),
Data type: Unsigned16
SERVO_S110-PN
(EPOS, Pos ctrl)
P-Group: Communications
Not for motor type: -
Min
7
Description:
Sets the send and receive telegram.
Value:
7:
9:
110:
1-176
SIEMENS telegram 390, PZD-2/2
SIEMENS telegram 391, PZD-3/7
SIEMENS telegram 392, PZD-3/15
SIEMENS telegram 393, PZD-4/21
SIEMENS telegram 394, PZD-3/3
Free telegram configuration with BICO
Standard telegram 1, PZD-2/2
Standard telegram 2, PZD-4/4
Standard telegram 3, PZD-5/9
Standard telegram 4, PZD-6/14
SIEMENS telegram 102, PZD-6/10
SIEMENS telegram 103, PZD-7/15
Free telegram configuration with BICO
Standard telegram 7, PZD-2/2
Standard telegram 9, PZD-10/5
SIEMENS telegram 110, PZD-12/7
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
999
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
999
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
999
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: 1520, 2420,
2422, 2424
Unit selection: -
Expert list: 1
Factory setting
999
Access level: 1
Func. diagram: 1520, 2420,
2422, 2423, 2424
Unit selection: -
Expert list: 1
Factory setting
999
Access level: 1
Func. diagram: 1520, 2420,
2422, 2423, 2424
Unit selection: -
Expert list: 1
Factory setting
999