Siemens SINAMICS S110 List Manual page 336

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p2200[0...n]
BI: Technology controller enable / Tec_ctrl enable
SERVO_S110-CAN
Can be changed: T
(Tech_ctrl),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-
Description:
Sets the signal source to switch in/switch out the technology controller.
The technology controller is switched in with a 1 signal.
p2201[0...n]
CO: Technology controller, fixed value 1 / Tec_ctr fix val 1
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-200.00 [%]
Description:
Sets the value for fixed value 1 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2202[0...n]
CO: Technology controller, fixed value 2 / Tec_ctr fix val 2
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-200.00 [%]
Description:
Sets the value for fixed value 2 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2203[0...n]
CO: Technology controller, fixed value 3 / Tec_ctr fix val 3
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-200.00 [%]
Description:
Sets the value for fixed value 3 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
1-336
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: DDS, p0180
Units group: 9_1
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dynamic index: DDS, p0180
Units group: 9_1
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dynamic index: DDS, p0180
Units group: 9_1
Scaling: PERCENT
Max
200.00 [%]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 7950
Unit selection: p0595
Expert list: 1
Factory setting
10.00 [%]
Access level: 2
Func. diagram: 7950
Unit selection: p0595
Expert list: 1
Factory setting
20.00 [%]
Access level: 2
Func. diagram: 7950
Unit selection: p0595
Expert list: 1
Factory setting
30.00 [%]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents