<1> For p1400.4 = 0 the torque limits for the positive and negative torque direction (upwards and downwards) are compatible with MASTERDRIVES and MICROMASTER 4.
"Normal case": If neither dynamic limits nor offsets are required, the upper torque limit is entered via p1520 and the lower via p1521 (as a negative value).
<2>
Danger:
Negative values at
A
or positive values at
!
<3> The limiter ensures that the limits do not mutually "overtake" one another.
<4> For the manufacturer-specific PROFIdrive telegrams 102 und 103, r1543 is switched in here [5610.4].
1
2
DO: SERVO
Servo control - Upper/lower torque limit
Upper torque limit
M_max upper/mot
p1522[C]
p1520[D]
(1520)
M_max up/mot scal
p1528[C]
p1524[D]
(1524)
e.g. from MOMRED
<4>
M_lim var/fixS_src
p1551[C]
(1)
Lower torque limit
M_max lower/regen
p1523[C]
p1521[D]
(1521)
M_max low/gen scal
p1529[C]
p1525[D]
(1525)
e.g. from MOMRED
<4>
B
represent a minimum torque for the other torque direction and can cause the motor to accelerate uncontrollably.
With
<
B , Fault F07090 is initiated, which can also be disabled.