Note:
You can change the default properties of a fault or alarm by setting parameters.
References: /FH3
The list of faults and alarms (see Chapter 3.2) provides information in relation to
the properties of a message that have been set as standard. If the properties of a
specific message are changed, the corresponding information may have to be
modified in this list.
Fault location (optional): Name
The fault location (optional), the name of the fault or alarm, and the message
number are all used to identify the message (e.g. with the commissioning soft-
ware).
Message value:
The information provided under the message value tells you about the composi-
tion of the fault/alarm value.
Example:
Message value: Component number: %1, cause of fault: %2
This message value contains information about the component number and
cause of the fault. The entries %1 and %2 are placeholders, which are filled
appropriately in online operation (e.g. with the commissioning software).
Drive object:
Each message (fault/alarm) specifies the drive object in which it can be found.
A message can belong to either one, several, or all drive objects.
Reaction: Default fault reaction (adjustable fault reaction)
Specifies the default reaction in the event of a fault.
The optional parentheses indicate whether the default fault reactions can be
changed and which fault reactions can be adjusted via parameters (p2100,
p2101).
Note:
See Chapter 3.1.1
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
SINAMICS S110 Function Manual
Chapter "Diagnostics"
Faults and alarms
Overview of faults and alarms