p1958[0...n]
Rotating measurement ramp-up/ramp-down time / Rot meas t_r up/dn
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
-1.00 [s]
Description:
Sets the ramp-up/ramp-down time for the rotating measurement.
The following applies for negative values:
When the function module "extended setpoint channel" is activated (r0108.8 = 1), the maximum of the ramp-
up/ramp-down time of the setpoint channel becomes effective. When this function module is inactive, then no ramp-
up/ramp-down time is effective.
The following applies for positive values:
The selected ramp-up/ramp-down time becomes effective.
Recommend.:
A ramp-up/ramp-down time should not be activated for the motor data identification (p1958 = 0) as long as this can
be safely done without incurring any danger. This means that the identification is complete and more accurate.
When the ramp-up/ramp-down time is activated, the following steps of the rotating motor data identification are not
executed:
- p1959.5 (identifying the q inductance)
- p1959.7 (identifying the reluctance torque constant)
Dependency:
Refer to: p1959, p1960
p1959[0...n]
Rotating measurement configuration / Rot meas config
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: REL
Min
-
Description:
Sets the configuration of the rotating measurement.
Recommend.:
A direction inhibit should not be activated for the rotating measurement (p1959.14 = 1 and p1959.15 = 1) as long as
this can be done without incurring any danger. This means that the identification is complete and more accurate.
When the direction inhibit is activated, the reluctance torque constant (p1959.7) is not identified and the angular
commutation offset (p1959.10, p0431) is inaccurately determined. The reluctance torque constant (p1959.7) is also
not identified in encoderless operation.
Bit field:
Bit
Signal name
00
Reserved
01
Identify the saturation characteristic
02
Identify the moment of inertia
05
Identify the q inductance
06
Identify the torque constant
07
Identify the reluctance torque constant
08
Identify the q inductance at the test stand
09
Identify the magnetizing current / magnetiz-
ing inductance
10
Identify the commutation angle and direc-
tion of rotation
11
Identify rotor resistance
14
Positive direction permitted
15
Negative direction permitted
Dependency:
Refer to: p1958, p1960
Notice:
The step p1959.8 (identify q inductance on the test stand) may only be selected if the drive can be kept at zero
speed or at a fixed speed either using a test stand or other mechanical measures.
During steps p1959.2 (identifying the moment of inertia) and p1959.6 (identifying the torque constant) the Vdc_min
controller is disabled (p1240).
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
999999.00 [s]
Calculated: CALC_MOD_ALL
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Parameter
List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-1.00 [s]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 1110 1110 0111 bin
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
1-275