Siemens SINAMICS S110 List Manual page 297

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Dependency:
Refer to: p2051, p2061
Note:
IF1: Interface 1
r2054
PROFIBUS status / PB status
CU_S110-DP
Can be changed: -
Data type: Integer16
P-Group: Communications
Not for motor type: -
Min
0
Description:
Status display for the PROFIBUS interface.
Value:
0:
1:
2:
3:
4:
Note:
Re r2054 = 3:
In state 3 (the LED flashes green), a cyclic connection has been established to the PROFIBUS master; however,
one of the following prerequisites is missing for cyclic operation:
- No setpoints are being received as the PROFIBUS master is in the STOP condition.
Only for clock-cycle synchronous operation, the following applies:
- The drive is not in synchronism as the global control (GC) has an error.
Re r2054 = 4:
In the status 4 (LED green), the cyclic connection to the PROFIBUS master has been established and setpoints are
being received. The clock cycle synchronization is OK, the global control (GC) is error-free.
This state does not provide any statement regarding the quality of the clock cycle synchronous sign-of-life charac-
ters on the drive objects.
r2055[0...2]
PROFIBUS diagnostics standard / PB diag standard
CU_S110-DP
Can be changed: -
Data type: Unsigned16
P-Group: Communications
Not for motor type: -
Min
-
Description:
Diagnostics display for the PROFIBUS interface.
Index:
[0] = Master bus address
[1] = Master input total length bytes
[2] = Master output total length bytes
r2057
PROFIBUS address switch diagnostics / PB addr diagn
CU_S110-DP
Can be changed: -
Data type: Unsigned16
P-Group: Communications
Not for motor type: -
Min
-
Description:
Displays the setting of the PROFIBUS address switch "DP ADDRESS" on the Control Unit.
Dependency:
Refer to: p0918
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
OFF
No connection (search for baud rate)
Connection OK (baud rate found)
Cyclic connection with master (data exchange)
Cyclic data OK
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
4
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: 2410
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 2410
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 2410
Unit selection: -
Expert list: 1
Factory setting
-
1-297