Parameter
List of parameters
p2585
EPOS jog 1 setpoint velocity / Jog 1 v_set
SERVO_S110-CAN
Can be changed: U, T
(EPOS),
Data type: Integer32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-40000000 [1000 LU/min]
Description:
Sets the setpoint velocity for jog 1.
Dependency:
Refer to: p2587, p2589, p2591
p2586
EPOS jog 2 setpoint velocity / Jog 2 v_set
SERVO_S110-CAN
Can be changed: U, T
(EPOS),
Data type: Integer32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-40000000 [1000 LU/min]
Description:
Sets the setpoint velocity for jog 2.
Dependency:
Refer to: p2588, p2590, p2591
p2587
EPOS jog 1 traversing distance / Jog 1 distance
SERVO_S110-CAN
Can be changed: U, T
(EPOS),
Data type: Unsigned32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
0 [LU]
Description:
Sets the traversing distance for incremental jog 1.
Dependency:
Refer to: p2585, p2589, p2591
Note:
Incremental jog 1 is started with BI: p2591 = 1 signal and BI: p2589 = 0/1 signal.
With BI: p2589 = 0 signal, incremental jog is interrupted.
p2588
EPOS jog 2 traversing distance / Jog 2 distance
SERVO_S110-CAN
Can be changed: U, T
(EPOS),
Data type: Unsigned32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
0 [LU]
Description:
Sets the traversing distance for incremental jog 2.
Dependency:
Refer to: p2586, p2590, p2591
Note:
Incremental jog 2 is started with BI: p2591 = 1 signal and BI: p2590 = 0/1 signal.
With BI: p2590 = 0 signal, incremental jogging is interrupted.
1-382
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
40000000 [1000 LU/min]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
40000000 [1000 LU/min]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
2147482647 [LU]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
2147482647 [LU]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: 3610
Unit selection: -
Expert list: 1
Factory setting
-300 [1000 LU/min]
Access level: 1
Func. diagram: 3610
Unit selection: -
Expert list: 1
Factory setting
300 [1000 LU/min]
Access level: 1
Func. diagram: 3610
Unit selection: -
Expert list: 1
Factory setting
1000 [LU]
Access level: 1
Func. diagram: 3610
Unit selection: -
Expert list: 1
Factory setting
1000 [LU]