Parameter
List of parameters
p2625
BI: EPOS traversing block selection, bit 0 / Trav_blk sel bit 0
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source to select the traversing block, bit 0.
Dependency:
Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2626, p2627, p2628, p2629, p2630
p2626
BI: EPOS traversing block selection, bit 1 / Trav_blk sel bit 1
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source to select the traversing block, bit 1.
Dependency:
Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2625, p2627, p2628, p2629, p2630
p2627
BI: EPOS traversing block selection, bit 2 / Trav_blk sel bit 2
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source to select the traversing block, bit 2.
Dependency:
Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2625, p2626, p2628, p2629, p2630
p2628
BI: EPOS traversing block selection, bit 3 / Trav_blk sel bit 3
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source to select the traversing block, bit 3.
Dependency:
Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2625, p2626, p2627, p2629, p2630
1-394
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: 3616, 3640
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 3616, 3640
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 3616, 3640
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 3616, 3640
Unit selection: -
Expert list: 1
Factory setting
0