Parameter
List of parameters
p0571[0...49]
Inhibit list, motor/closed-loop control parameter calculation / Inhib list calc
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Applications
Not for motor type: -
Min
0
Description:
The inhibit list contains parameters that should be withdrawn from the automatic motor and closed-loop control
parameter calculation (p0340, p0578).
Value:
0:
348:
600:
640:
1082: Maximum speed
1441: Actual speed smoothing time
1460: Speed controller P gain
1462: Speed controller integral time
1470: Speed controller P gain, encoderless
1472: Speed controller integral time, encoderless
1520: Torque limit upper/motoring
1521: Torque limit lower/regenerative
1530: Power limit motoring
1531: Power limit regenerative
1590: Flux controller P gain
1592: Flux controller integral time
1656: Activates current setpoint filter
2141: Speed threshold 1
2142: Hysteresis speed 1
Note:
p0570 defines the number of entries (starting at index 0) for which the inhibit should apply. p0572 can be used to
define for which drive data sets the inhibit list should apply.
If a motor data set is entered into a parameter number, then this is not overwritten as soon as only one drive data
set refers to the motor data set (p0186).
p0572[0...n]
Activate inhibit list / Act inhib list
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Applications
Not for motor type: -
Min
0
Description:
Enable ID as to whether the parameters of the inhibit list p0571 should be overwritten when calculating the motor
and closed-loop control parameters for the particular drive data set (index = DDS).
Value:
0:
1:
Note:
0: The automatic calculation (p0340, p0578) also overwrites the parameters of list p0571.
1: The automatic calculation (p0340, p0578) does not overwrite the parameters of list p0571.
p0573
Inhibit automatic reference value calculation / Inhibit calc
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Applications
Not for motor type: -
Min
0
Description:
Setting to inhibit the calculation of reference parameters (e.g. p2000) when automatically calculating the motor and
closed-loop control parameters (p0340, p3900).
1-130
No parameter
Speed at the start of field weakening Vdc = 600 V
Motor temperature sensor
Current limit
No
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
2142
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
1
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0