16
Characteristic data spindle available
17
Characteristic data clamping cycle counter
available
19
Characteristic data operating hours counter
available
20
Characteristic data temperature diagnostics
available
22
Characteristic data speed/torque matrix
available
30
Characteristic data sensor description avail-
able
31
Characteristic data sensor calibration data
available
p5007
Spindle file system selection / File sys select
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the files to adapt the file system.
Bit field:
Bit
Signal name
01
Result data clamping cycle thresholds
selected
02
Result data clamping cycle counter selected Yes
03
Result data operating hours counter
selected
04
Result data temperature diagnostics
selected
05
Result data real time clock synchronization
selected
06
Result data speed/torque matrix selected
17
Characteristic data clamping cycle counter
selected
19
Characteristic data operating hours counter
selected
20
Characteristic data temperature diagnostics
selected
22
Characteristic data speed/torque matrix
selected
p5009
Adapt spindle file system / Adapt file sys
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to adapt the file system on the non-volatile memory.
Example:
The result data "clamping cycle thresholds" are available (r5005.1 = 1) and should be reset.
--> set p5007.1 = 1: select result data "clamping cycle thresholds".
--> set p5009 = 1: initiate "reset" function for the file selected in p5007.
--> p5009 = 40: feedback signal during "operation running".
--> p5009 = 20: feedback signal for a successfully completed operation.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
53
Parameter
List of parameters
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 0000
0000 0000 0000 bin
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0