Siemens SINAMICS S110 List Manual page 116

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r0466[0...27]
Encoder 2 identification number/serial number / Enc2 ID_no/Ser_no
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned8
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the identification/serial number of encoder 2.
Index 0 = first character of the identification number
...
Index x = 20 hex (blank) --> separation between the identification number of serial number
Index x + 1 = 2F hex (slash) --> separation between the identification number of serial number
Index x + 2 = 20 hex (blank) --> separation between the identification number of serial number
Index x + 3 = first character of the serial number
...
Index y with contents = last character of the serial number
Dependency:
Refer to: r0460, r0461, r0462, r0463, r0464
Notice:
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
Note:
The individual characters of the identification number/serial number are available coded as ASCII characters.
r0470[0...2]
Redundant coarse value valid bits / Valid bits
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the valid bits of the redundant coarse position value.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p9323, p9523
r0471[0...2]
Redundant coarse value fine resolution bits / Fine bit
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the number of valid bits for the fine resolution of the redundant coarse position value.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p9324, p9524
1-116
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents