Siemens SINAMICS S110 List Manual page 266

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r1732
CO: Direct-axis voltage setpoint / Direct U set
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Vrms]
Description:
Displays the direct-axis voltage setpoint Ud.
r1733
CO: Quadrature-axis voltage setpoint / Quad U set
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Vrms]
Description:
Displays the quadrature-axis component of voltage setpoint Uq.
p1752[0...n]
Motor model changeover speed operation with encoder / MotMod n_chgov enc
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
0.00 [rpm]
Description:
Sets the speed to change over the motor model for operation with encoder.
Dependency:
Refer to: p1756
Note:
Induction motor (ASM):
The motor model is influenced for speeds/velocities greater than p1752.
Synchronous motor (SRM):
A monitoring (F07412) is activated for speeds/velocities greater than p1752.
The motor model is additionally influenced when kT adaptation is activated (p1780.3 = 1).
p1755[0...n]
Motor model changeover speed encoderless operation / MotMod n_chgSnsorl
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
0.00 [rpm]
Description:
Sets the speed to change over the motor model to encoderless operation.
Dependency:
Refer to: p1756
Note:
The changeover speed applies for the changeover between open-loop and closed-loop control mode.
1-266
Calculated: -
Dynamic index: -
Units group: 5_1
Scaling: p2001
Max
- [Vrms]
Calculated: -
Dynamic index: -
Units group: 5_1
Scaling: p2001
Max
- [Vrms]
Calculated: CALC_MOD_REG
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated: CALC_MOD_REG
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 1630, 5714,
6714, 5718
Unit selection: p0505
Expert list: 1
Factory setting
- [Vrms]
Access level: 3
Func. diagram: 1630, 5714,
5718, 6714, 6719
Unit selection: p0505
Expert list: 1
Factory setting
- [Vrms]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
210000.00 [rpm]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
210000.00 [rpm]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents