Dependency:
Refer to: p1317, p1338, p1349
Note:
The filter time constant must be greater than the oscillation period of the oscillation to be dampened.
p1345[0...n]
DC braking proportional gain / DCBRK Kp
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: V/f open-loop control
Not for motor type: -
Min
0.000
Description:
Sets the proportional gain for DC braking (p1230, p1231).
Dependency:
Refer to: p1346
Note:
Current controller adaptation is not effective for DC braking.
p1346[0...n]
DC braking, integral time / DCBRK Tn
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: V/f open-loop control
Not for motor type: -
Min
0.000 [ms]
Description:
Sets the integral time for DC braking (p1230, p1231).
Dependency:
Refer to: p1345
Note:
For p1346 = 0, the following applies:
The integral time of DC braking is de-activated.
p1349[0...n]
U/f mode resonance damping maximum frequency / Uf res_damp f_max
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: V/f open-loop control
Not for motor type: -
Min
0.00 [Hz]
Description:
Sets the maximum output frequency for resonance damping for U/f control.
Resonance damping is inactive above this output frequency.
Dependency:
Refer to: p1338, p1339
Note:
Resonance damping is active in the following ranges:
- Active: 3.1 Hz ... p1349
- Build-up (linear): 3.1 ... 4.77 Hz
- Reduction (linear): 0.95 * p1349 ... p1349
p1400[0...n]
Speed control configuration / n_ctrl config
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the configuration for the closed-loop speed control.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: CALC_MOD_CON
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
100000.000
Calculated: CALC_MOD_CON
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
50.000 [ms]
Calculated: CALC_MOD_ALL
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
3000.00 [Hz]
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.000
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.030 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
3000.00 [Hz]
Access level: 2
Func. diagram: 1590, 5490
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 0000
0011 1010 0000 bin
1-235