Value:
0:
1:
Notice:
The inhibit for the reference value calculation is canceled when new motor parameters (e.g. p0305) are entered and
only one drive data set exists (p0180 = 1). This is the case during initial commissioning.
Once the motor and control parameters have been calculated (p0340, p3900), the inhibit for the reference value
calculation is automatically re-activated.
Note:
If value = 0:
The automatic calculation (p0340, p3900) overwrites the reference parameters.
If value = 1:
The automatic calculation (p0340, p3900) does not overwrite the reference parameters.
p0578[0...n]
Calculate technology-dependent parameters / Calc tec par
SERVO_S110-CAN,
Can be changed: C2(5), T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Applications
Not for motor type: -
Min
0
Description:
This parameter is used to calculate all parameters that depend on the technology of the application (p0500).
All of the parameters are calculated that can also be determined using p0340 = 5.
Value:
0:
1:
Note:
At the end of the calculations, p0578 is automatically set to 0.
p0580
Measuring probe, input terminal / MT input terminal
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the input terminal for the measuring probe for speed actual value measurement.
Value:
0:
1:
2:
3:
7:
Dependency:
Refer to: p0728
Refer to: A07498
Note:
The terminal must be set as input (p0728).
If a parameter change is rejected, a check should be performed as to whether the input terminal is already being
used in p0488, p0489, p0493, p0494, p0495, p0680, p2517 or p2518.
DI/DO: Bidirectional Digital Input/Output
p0595
Selecting technological units / Select tech units
SERVO_S110-CAN
Can be changed: C2(5)
(Tech_ctrl),
Data type: Integer16
SERVO_S110-DP
P-Group: Applications
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
1
Description:
Selects the units for the parameters of the technology controller.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
No
Yes
No calculation
Complete calculation
No measuring probe
DI/DO 9 (X132.2)
DI/DO 10 (X132.3)
DI/DO 11 (X132.4)
DI/DO 8 (X132.1)
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
1
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
7
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
32
Parameter
List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
1-131