Parameter
List of parameters
p2612
BI: EPOS search for reference, reference cam / Ref_cam
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the reference cam.
Dependency:
Refer to: p2607
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2613
BI: EPOS search for reference reversing cam minus / Rev minus
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency:
Refer to: p2614
Note:
If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
p2614
BI: EPOS search for reference reversing cam plus / Rev plus
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency:
Refer to: p2613
Note:
If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
p2615
EPOS maximum number of traversing blocks / Trav_block qty max
SERVO_S110-CAN
Can be changed: C2(17)
(EPOS),
Data type: Unsigned8
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
1
Description:
Sets the maximum number of traversing blocks that are available.
Dependency:
Refer to: p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
1-390
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
16
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: 3612
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 3612
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 1
Func. diagram: 3612
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 1
Func. diagram: 3616
Unit selection: -
Expert list: 1
Factory setting
16