Siemens SINAMICS S110 List Manual page 36

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r0024
Output frequency smoothed / f_outp smooth
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
- [Hz]
Description:
Displays the smoothed converter frequency.
Dependency:
Refer to: r0066
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The output frequency is available smoothed (r0024) and unsmoothed (r0066).
r0025
CO: Output voltage smoothed / U_outp smooth
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
- [Vrms]
Description:
Displays the smoothed output voltage of the power unit.
Dependency:
Refer to: r0072
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The output voltage is available smoothed (r0025) and unsmoothed (r0072).
r0026
CO: DC link voltage smoothed / Vdc smooth
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
- [V]
Description:
Displays the smoothed actual value of the DC link voltage.
Dependency:
Refer to: r0070
Notice:
When measuring a DC link voltage < 200 V, for the Power Module (e.g. PM340) a valid measured value is not sup-
plied. In this case, when an external 24 V power supply is connected, a value of approx. 24 V is displayed in the dis-
play parameter.
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The DC link voltage is available smoothed (r0026) and unsmoothed (r0070).
1-36
Calculated: -
Dynamic index: -
Units group: -
Scaling: p2000
Max
- [Hz]
Calculated: -
Dynamic index: -
Units group: -
Scaling: p2001
Max
- [Vrms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: p2001
Max
- [V]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 1690, 5300,
5730, 6799
Unit selection: -
Expert list: 1
Factory setting
- [Hz]
Access level: 2
Func. diagram: 1690, 5730,
6799
Unit selection: -
Expert list: 1
Factory setting
- [Vrms]
Access level: 2
Func. diagram: 5730, 8750,
8850, 8950
Unit selection: -
Expert list: 1
Factory setting
- [V]

Hide quick links:

Advertisement

Table of Contents
loading