Siemens SINAMICS S110 List Manual page 74

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
Note:
The value depends on the device type and the selected rated voltage p0210.
For booksize units, the following applies:
The undervoltage threshold can be reduced with p0278.
r0297
DC link voltage overvoltage threshold / Vdc U_upper_thresh
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
- [V]
Description:
If the DC link voltage exceeds the threshold specified here, the drive unit is tripped due to DC link overvoltage.
Dependency:
Refer to: F30002
p0300[0...n]
Motor type selection / Mot type sel
SERVO_S110-CAN,
Can be changed: C2(1, 3)
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
0
Description:
Selects the motor type or start to read in the motor parameters for a motor with DRIVE-CLiQ (p0300 = 10000).
For p0300 < 10000 the following applies:
The first digit of the parameter value always defines the general motor type and corresponds to the third-party
motor belonging to a motor list:
1 = Rotating induction motor
2 = Rotating synchronous motor
The type information must be entered to filter motor-specific parameters and to optimize the operating characteris-
tics and behavior. For example, for synchronous motors, power factor (p0308) is neither used nor displayed (in the
BOP/AOP).
Value:
0:
1:
2:
104:
107:
108:
111:
200:
206:
207:
222:
236:
237:
444:
10000: Motor with DRIVE-CLiQ
10001: Motor with DRIVE-CLiQ 2nd data set
Dependency:
When the motor type is changed, the code number in p0301 may be reset to 0.
If p0300 is changed during quick commissioning (p0010 = 1), then the matching technological application (p0500) is
automatically pre-assigned. This does not occur when commissioning the motor (p0010 = 3). If p0300 = 10000 is
written for a parameter download, p0500 is pre-assigned with DRIVE-CLiQ corresponding to the motor type.
Refer to: p0301
Caution:
If a catalog motor is selected (p0300 >= 100) and an associated motor code number (p0301), then the parame-
ters,that are associated with this list cannot be changed (write protection). The write protection is canceled if the
motor type p0300 is set to a non-Siemens motor that matches p0301 (e.g. p0300 = 2 for p0301 = 2xxxx). Write pro-
tection is automatically canceled when the results of motor data identification are copied to the motor parameters.
1-74
No motor
Induction motor (rotating)
Synchronous motor (rotating, permanent-magnet)
1PH4 induction motor
1PH7 induction motor
1PH8 induction motor
Induction motor (rotary) for OEMs
1PH8 synchronous motor
1FT6 synchronous motor
1FT7 synchronous motor
Synchronous motor (rotary) for OEMs
1FK6 synchronous motor
1FK7 synchronous motor
Synchronous motor (linear) for OEMs
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [V]
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
10001
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: 8750, 8760,
8850, 8864, 8950, 8964
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 1
Func. diagram: 6310
Unit selection: -
Expert list: 1
Factory setting
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents