Siemens SINAMICS S110 List Manual page 173

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p0868
Power unit DC switch debounce time / PU DC sw t_deboun
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Commands
Not for motor type: -
Min
0 [ms]
Description:
Sets the debounce time for the DC circuit breaker for Motor Modules in "chassis" format.
Note:
The following applies if p0868 = 65000 ms:
The debounce time defined internally in the power unit's EEPROM is implemented.
p0894
Parking pre-setting / Parking pre-set
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Pre-setting for the "Parking axis" and "Parking encoder" function.
Bit field:
Bit
Signal name
00
Default with interconnection
Dependency:
Refer to: p0480, p0897
Note:
Re bit 00:
If there is at least one BICO interconnection for "Parking axis" or "Parking encoder", this default setting is taken into
consideration during power-up.
r0896.0
BO: Parking axis, status word / Parking axis, ZSW
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned8
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the status word for the "parking axis" function.
Bit field:
Bit
Signal name
00
Parking axis active
Dependency:
Refer to: p0897
p0897
BI: Parking axis selection / Parking axis sel
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Sets the signal source to select the "parking axis" function.
Dependency:
BI: p0897 = 0 signal
The function "parking axis" is not selected.
BI: p0897 = 1 signal
The function "parking axis" is selected.
Refer to: r0896
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65000 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Park
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
65000 [ms]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
FP
Do not park
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0