Parameter
List of parameters
p0795
CU digital inputs simulation mode / CU DI simulation
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the simulation mode for digital inputs.
Bit field:
Bit
Signal name
00
DI 0 (X133.1)
01
DI 1 (X133.2)
02
DI 2 (X133.3)
03
DI 3 (X133.4)
08
DI/DO 8 (X132.1)
09
DI/DO 9 (X132.2)
10
DI/DO 10 (X132.3)
11
DI/DO 11 (X132.4)
16
DI 16 (X130.1)
17
DI 17 (X130.2)
18
DI 18 (X130.4)
19
DI 19 (X130.5)
20
DI 20 (X131.1)
21
DI 21 (X131.2)
22
DI 22 (X131.4)
Dependency:
The setpoint for the input signals is specified using p0796.
Refer to: p0796
Notice:
If a digital input is used as signal source for the function "STO" (BI: p9620) then it is not permissible to select the
simulation mode and this is rejected.
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
p0796
CU digital inputs simulation mode setpoint / CU DI simul setp
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the setpoint for the input signals in the digital input simulation mode.
Bit field:
Bit
Signal name
00
DI 0 (X133.1)
01
DI 1 (X133.2)
02
DI 2 (X133.3)
03
DI 3 (X133.4)
08
DI/DO 8 (X132.1)
09
DI/DO 9 (X132.2)
10
DI/DO 10 (X132.3)
11
DI/DO 11 (X132.4)
16
DI 16 (X130.1)
17
DI 17 (X130.2)
1-156
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
High
High
High
High
High
High
High
High
High
High
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: 1510, 2020,
2030, 2031, 2100, 2120, 2130,
2131, 2132, 2133
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 0000
0000 0000 0000 bin
0 signal
FP
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Terminal eval.
-
Access level: 2
Func. diagram: 1510, 2020,
2030, 2031, 2100, 2120, 2130,
2131, 2132, 2133
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 0000
0000 0000 0000 bin
0 signal
FP
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-