Siemens SINAMICS S110 List Manual page 713

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p20223[0...1]
CI: NSW 1 inputs / NSW 1 inputs
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32 / FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Sets the signal source of input quantities X0 and X1 of instance NSW 1 of the numeric changeover switch.
Index:
[0] = Input X0
[1] = Input X1
p20224
BI: NSW 1 switch setting I / NSW 1 sw_setting
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32 / Binary
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Sets the signal source of the switch setting I of instance NSW 1 of the numeric changeover switch.
r20225
CO: NSW 1 output Y / NSW 1 output Y
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Display parameter for output quantity Y of instance NSW 1 of the numeric changeover switch.
p20226
NSW 1 run-time group / NSW 1 RTG
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Integer16
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
0
Description:
Setting parameter for the run-time group in which the instance NSW 1 of the numeric changeover switch is to be
called.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
9999
Parameter
List of parameters
Access level: 1
Func. diagram: 7250
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 7250
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 7250
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: 7250
Unit selection: -
Expert list: 1
Factory setting
9999
1-713