Siemens SINAMICS S110 List Manual page 420

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p2900[0...n]
CO: Fixed value 1 [%] / Fixed value 1 [%]
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Free function blocks
Not for motor type: -
Min
-10000.00 [%]
Description:
Sets a fixed percentage.
Dependency:
Refer to: p2901, p2930
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can be used to interconnect a scaling function (e.g. scaling of the main setpoint)
p2901[0...n]
CO: Fixed value 2 [%] / Fixed value 2 [%]
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Free function blocks
Not for motor type: -
Min
-10000.00 [%]
Description:
Sets a fixed percentage.
Dependency:
Refer to: p2900, p2930
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can be used to interconnect a scaling function (e.g. scaling of the supplementary setpoint)
r2902[0...14]
CO: Fixed values [%] / Fixed values [%]
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Free function blocks
Not for motor type: -
Min
- [%]
Description:
Signal sources for frequently used percentage values.
Index:
[0] = Fixed value +0 %
[1] = Fixed value +5 %
[2] = Fixed value +10 %
[3] = Fixed value +20 %
[4] = Fixed value +50 %
[5] = Fixed value +100 %
[6] = Fixed value +150 %
[7] = Fixed value +200 %
[8] = Fixed value -5 %
[9] = Fixed value -10 %
[10] = Fixed value -20 %
[11] = Fixed value -50 %
[12] = Fixed value -100 %
[13] = Fixed value -150%
[14] = Fixed value -200 %
Dependency:
Refer to: p2900, p2901, p2930
Note:
The signal sources can, for example, be used to interconnect scalings.
1-420
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: PERCENT
Max
10000.00 [%]
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: PERCENT
Max
10000.00 [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
- [%]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 1021
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 3
Func. diagram: 1021
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 1
Func. diagram: 1021
Unit selection: -
Expert list: 1
Factory setting
- [%]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents