Parameter
List of parameters
p1545[0...n]
BI: Activates travel to a fixed stop / TfS activation
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Commands
Not for motor type: REL
Min
-
Description:
Sets the signal source to activate/de-activate the "travel to fixed stop" function
1: Travel to fixed stop is active
0: Travel to fixed stop is inactive
Dependency:
Refer to: p1542, r1543, p1544
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1546
Speed threshold motoring/regenerating / n_thresh mot/regen
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the speed threshold for the motoring/regenerative limit.
For speeds where the absolute value is less than p1546, then the following applies:
- For p1400.13 = 0: Motoring limit (speed threshold is compared to the speed actual value).
- For p1400.13 = 1: Regenerative limiting (speed threshold is compared to the speed setpoint).
r1549
CO: Stall power actual value / P_stall
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
- [kW]
Description:
Displays the instantaneous stall power.
Dependency:
Refer to: p0326
Note:
The stall power is influenced by p0326, p0353, p0354 and p0356.
p1550[0...n]
BI: Transfer actual torque as torque offset / Accept act torque
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
For a positive edge, the actual torque (r0079[0]) at this instant in time is used instead of the torque offset from
p1532 as long as p1550 remains at 1.
1-258
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated: -
Dynamic index: -
Units group: 14_5
Scaling: r2004
Max
- [kW]
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 2520, 3617,
8012
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
20.00 [rpm]
Access level: 3
Func. diagram: 5640
Unit selection: p0505
Expert list: 1
Factory setting
- [kW]
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
9718.23