p2810[0...1]
BI: AND logic operation inputs / AND inputs
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Functions
Not for motor type: -
Min
-
Description:
Sets the signal sources for the inputs of the AND logic operation.
Dependency:
Refer to: r2811
Note:
[0]: AND logic operation, input 1 --> the result is displayed in r2811.0.
[1]: AND logic operation, input 2 --> the result is displayed in r2811.0.
r2811.0
CO/BO: AND logic operation result / AND result
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Functions
Not for motor type: -
Min
-
Description:
Displays the result of the AND logic operation
Bit field:
Bit
Signal name
00
AND logic operation result
Dependency:
Refer to: p2810
p2816[0...1]
BI: OR logic operation inputs / OR inputs
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Functions
Not for motor type: -
Min
-
Description:
Sets the signal sources for the inputs of the OR logic operation.
Dependency:
Refer to: r2817
Note:
[0]: OR logic operation, input 1 --> the result is displayed in r2817.0.
[1]: OR logic operation, input 2 --> the result is displayed in r2817.0.
r2817.0
CO/BO: OR logic operation result / OR result
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Functions
Not for motor type: -
Min
-
Description:
Displays the result of the OR logic operation.
Bit field:
Bit
Signal name
00
OR logic operation result
Dependency:
Refer to: p2816
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Parameter
List of parameters
Access level: 2
Func. diagram: 2634
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2634
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
Access level: 2
Func. diagram: 2634
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2634
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
1-419