Siemens SINAMICS S110 List Manual page 105

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p0435[0...n]
Encoder SSI alarm bit / Enc SSI alarm bit
SERVO_S110-CAN,
Can be changed: C2(4)
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the position and level of the alarm bit in the SSI protocol.
Notice:
The bit may only be positioned before (p0446) or after (p0448) the absolute value in the SSI protocol.
Note:
Value = dcba
ba: Position of the alarm bit in protocol (0 ... 63).
c: Level (0: Low level, 1: High level).
d: State of the evaluation (0: Off, 1: On).
Example:
p0435 = 1014
--> The evaluation is switched in and the alarm bit is at position 14 with a low level.
p0435 = 1114
--> The evaluation is switched in and the alarm bit is at position 14 with a high level.
p0436[0...n]
Encoder SSI parity bit / Enc SSI parity bit
SERVO_S110-CAN,
Can be changed: C2(4)
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the position and parity of the parity bit in the SSI protocol.
Notice:
The bit may only be positioned before (p0446) or after (p0448) the absolute value in the SSI protocol.
Note:
Value = dcba
ba: Position of the parity bit in the protocol (0 ... 63).
c: Parity (0: even, 1: uneven).
d: State of the evaluation (0: Off, 1: On).
Example:
p0436 = 1015
--> The evaluation is switched in and the parity bit is at position 15 with even parity.
p0436 = 1115
--> The evaluation is switched in and the parity bit is at position 15 with uneven parity.
p0437[0...n]
Sensor Module configuration extended / SM config ext
SERVO_S110-CAN,
Can be changed: C2(4)
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Sets the extended configuration of the Sensor Module.
Bit field:
Bit
Signal name
00
Data logger
01
Zero mark edge detection
02
Correction position actual value XIST1
04
Edge evaluation bit 0
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0011 0000 0000 0000 0000
1000 0000 0000 bin
0 signal
FP
No
-
No
-
No
-
No
-
1-105

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents