r1936
Magnetizing inductance identified / L_H ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [mH]
Description:
Displays the identified magnetizing inductance(gamma equivalent circuit diagram).
Dependency:
Refer to: p1909, p1910, r1913, r1915, r1927, p1959, p1960, r1962, r1963
Note:
This value corresponds to the value of the transformed magnetizing inductance (r0382).
r1937[0...10]
Torque constant identified / kT ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [Nm/A]
Description:
Displays the identified torque constant/torque characteristic over the q current.
Index:
[0] = Torque constant identified
[1] = Torque characteristic identified measuring point 1
[2] = Torque characteristic identified measuring point 2
[3] = Torque characteristic identified measuring point 3
[4] = Torque characteristic identified measuring point 4
[5] = Torque characteristic identified measuring point 5
[6] = Torque characteristic identified measuring point 6
[7] = Torque characteristic identified measuring point 7
[8] = Torque characteristic identified measuring point 8
[9] = Torque characteristic identified measuring point 9
[10] = Torque characteristic identified measuring point 10
Dependency:
Refer to: r1938, r1939, p1959, p1960, r1969
Note:
- the value in r1937[0] corresponds to the torque constant (p0316) and was identified with the current in r1935[10].
If the reluctance torque is identified (p1959.7 = 1), the torque constant is identified with 150% rated current (p0305),
otherwise with 100% rated current.
- if indices r1937[1...10] are not equal to zero, they show the values of the torque characteristic identified for the cur-
rent in r1935[11...20]. The torque characteristic is identified in the range between rated current (p0305) and maxi-
mum current (p0640).
r1938
Voltage constant identified / kE ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [Vrms]
Description:
Displays the identified voltage constant.
Dependency:
Refer to: r1937, r1939, p1959, p1960, r1969
Note:
This value corresponds to the voltage constant (p0317).
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [mH]
Calculated: -
Dynamic index: -
Units group: 28_1
Scaling: -
Max
- [Nm/A]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [Vrms]
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [mH]
Access level: 3
Func. diagram: -
Unit selection: p0100
Expert list: 1
Factory setting
- [Nm/A]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [Vrms]
1-273

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents