Re bit 15:
The bit indicates whether the automatic parameterization (p0340 = 1, p3900 > 0) for the parameters of the extended
monitoring functions was carried out. If the bit is not set (e.g. when the configuration is activated (p0108.15)), the
parameterization is automatically carried out during booting even if r3925.0 is already 1.
p2150[0...n]
Hysteresis speed 3 / n_hysteresis 3
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
SERVO_S110-PN
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the hysteresis speed (bandwidth) for the following signals:
"|n_act| < speed threshold value 3" (BO: r2199.0)
"n_set >= 0" (BO: r2198.5)
"n_act >= 0" (BO: r2197.3)
Dependency:
Refer to: p2161, r2197, r2199
p2151[0...n]
CI: Speed setpoint for messages/signals / n_set for msg
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed setpoint for the following messages:
"Speed setpoint - actual value deviation within tolerance t_off" (BO: r2197.7)
"Ramp-up/ramp-down completed" (BO: r2199.5)
"|n_set| < p2161" (BO: r2198.4)
"n_set > 0" (BO: r2198.5)
Dependency:
Refer to: r2197, r2198, r2199
p2153[0...n]
Speed actual value filter time constant / n_act_filt T
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
0 [ms]
Description:
Sets the time constant of the PT1 element to smooth the speed / velocity actual value.
The smoothed actual speed/velocity is compared with the threshold values and is only used for messages and sig-
nals.
Dependency:
Refer to: r2169
p2154[0...n]
CI: Speed setpoint 2 / n_set 2
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the signal source for speed setpoint 2.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated:
CALC_MOD_LIM_REF
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: -
Max
300.00 [rpm]
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: p2000
Max
-
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
1000000 [ms]
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: p2000
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: 8010
Unit selection: p0505
Expert list: 1
Factory setting
2.00 [rpm]
Access level: 3
Func. diagram: 8010
Unit selection: -
Expert list: 1
Factory setting
1438[0]
Access level: 3
Func. diagram: 8010
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 3
Func. diagram: 8010
Unit selection: -
Expert list: 1
Factory setting
0
1-327