r0051.0...1
CO/BO: Drive Data Set DDS effective / DDS effective
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned8
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the effective Drive Data Set (DDS).
Bit field:
Bit
Signal name
00
DDS eff., bit 0
01
DDS eff., bit 1
Dependency:
Refer to: p0820, r0837
Note:
The drive data set changeover is suppressed when selecting the motor identification, during the rotating measure-
ment, the encoder calibration and the friction characteristic record.
r0056.1...15
CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the status word of the closed-loop control.
Bit field:
Bit
Signal name
01
De-magnetizing completed
04
Magnetizing completed
08
Field weakening active
14
Vdc_max controller active
15
Vdc_min controller active
Note:
Re bit 04:
The bit is immediately set after power-on
Exception:
For an induction motor with brake (except for p1215 = 2), the bit is only set when 60% of the reference flux is
reached.
r0060
CO: Speed setpoint before the setpoint filter / n_set before filt.
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
- [rpm]
Description:
Displays the actual speed setpoint at the input of the speed controller or U/f characteristic (after the interpolator).
Dependency:
Refer to: r0020
Note:
The speed setpoint is available smoothed (r0020) and unsmoothed (r0060).
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
ON
ON
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Parameter
List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
OFF
-
OFF
-
Access level: 3
Func. diagram: 1530, 2526
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
2701
No
-
No
-
No
-
Access level: 3
Func. diagram: 2701, 2704,
5020, 6030, 6799
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
1-45