Parameter
List of parameters
Note:
For the automatic calculation (p0340 = 1, p3900 > 0) an appropriate pre-assignment is only made if the parameter
is not inhibited from being overwritten using p0573 = 1.
If a BICO interconnection is established between different physical quantities, then the particular reference quanti-
ties are used as internal conversion factor.
p2006
Reference temp / Ref temp
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Communications
Not for motor type: -
Min
50.00 [°C]
Description:
Sets the reference quantity for temperature.
All temperatures specified as relative value are referred to this reference quantity.
The reference quantity in this parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
p2007
Reference acceleration / a_ref
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Communications
Not for motor type: -
Min
0.01 [rev/s²]
Description:
Sets the reference quantity for acceleration rates.
All acceleration rates specified as relative value are referred to this reference quantity.
The reference quantity in this parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
Note:
For the automatic calculation (p0340 = 1, p3900 > 0) an appropriate pre-assignment is only made if the parameter
is not inhibited from being overwritten using p0573 = 1. If a BICO interconnection is established between different
physical quantities, then the particular reference quantities are used as internal conversion factor.
The reference acceleration is calculated as follows:
Reference speed (p2000) converted from 1/min to 1/s divided by 1 s
--> p2007 = p2000 [rpm] / (60 [s/min] * 1 [s])
p2016[0...3]
CI: Comm IF USS PZD send word / Comm USS send word
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32 / Integer16
CU_S110-PN
P-Group: Communications
Not for motor type: -
Min
-
Description:
Selects the PZD (actual values) to be sent via the commissioning interface USS.
The actual values are displayed on an intelligent operator panel (IOP).
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
1-286
Calculated: CALC_MOD_ALL
Dynamic index: -
Units group: -
Scaling: -
Max
300.00 [°C]
Calculated: CALC_MOD_ALL
Dynamic index: -
Units group: -
Scaling: -
Max
500000.00 [rev/s²]
Calculated: -
Dynamic index: -
Units group: -
Scaling: 4000H
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.00 [°C]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.01 [rev/s²]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0