Siemens SINAMICS S110 List Manual page 343

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p2235[0...n]
BI: Technology controller motorized potentiometer raise setpoint /
Tec_ctrl mop raise
SERVO_S110-CAN
Can be changed: T
(Tech_ctrl),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Commands
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-
Description:
Sets the signal source to continually increase the setpoint for the motorized potentiometer of the technology control-
ler.
The setpoint change (CO: r2250) depends on the set ramp-up time (p2247) and the duration of the signal that is
present (BI: p2235).
Dependency:
Refer to: p2236
p2236[0...n]
BI: Technology controller motorized potentiometer lower setpoint /
Tec_ctrl mop lower
SERVO_S110-CAN
Can be changed: T
(Tech_ctrl),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Commands
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-
Description:
Sets the signal source to continually reduce the setpoint for the motorized potentiometer of the technology control-
ler.
The setpoint change (CO: r2250) depends on the set ramp-down time (p2248) and the duration of the signal that is
present (BI: p2236).
Dependency:
Refer to: p2235
p2237[0...n]
Technology controller motorized potentiometer maximum value / Tec_ctrl mop max
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-200.00 [%]
Description:
Sets the maximum value for the motorized potentiometer of the technology controller.
Dependency:
Refer to: p2238
p2238[0...n]
Technology controller motorized potentiometer minimum value / Tec_ctrl mop min
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-200.00 [%]
Description:
Sets the minimum value for the motorized potentiometer of the technology controller.
Dependency:
Refer to: p2237
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: DDS, p0180
Units group: 9_1
Scaling: -
Max
200.00 [%]
Calculated: -
Dynamic index: DDS, p0180
Units group: 9_1
Scaling: -
Max
200.00 [%]
Parameter
List of parameters
Access level: 3
Func. diagram: 7954
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 7954
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 7954
Unit selection: p0595
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 7954
Unit selection: p0595
Expert list: 1
Factory setting
-100.00 [%]
1-343

Hide quick links:

Advertisement

Table of Contents
loading