- port type
- number of ports of the port type
- component number of the associated/linked component
- number of the associated/linked port
- component number of the associated/linked component
- number of the associated port, etc.
Data on the next component:
- etc.
Dependency:
Refer to: p9902
Note:
The target topology can only be modified using the commissioning software.
Only for internal Siemens use.
The parameter is not displayed for the STARTER commissioning software.
Changes do not become effective until they have been accepted with p9428 = 1, or on change of status from p0009
= 101 to 0 or 111.
p9904
Topology comparison, acknowledge differences / Topo_compare ackn
CU_S110-CAN,
Can be changed: C1(1)
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Topology
Not for motor type: -
Min
0000 hex
Description:
If, when comparing the actual topology and target topology, only error has occurred, that can be acknowledged,
then using this parameter, a new comparison can be started - acknowledging the error in the target topology.
Differences that can be acknowledged:
- topology comparison, component shifted
- topology comparison, serial number of a component has been detected to be different (byte 3 = 1)
- topology comparison shows one component that is connected differently
The following parameter values are available:
p9904 = 1 --> the procedure is started.
p9904 = 0 after starting --> the procedure has been successfully completed.
p9904 = 1 after starting --> the procedure has not been successfully completed.
The possible causes for an unsuccessful procedure are located in bytes 4, 3, 2.
Byte 2:
Number of structural differences.
Byte 3:
Number of differences that can be acknowledged (p9904).
Byte 4:
Number of differences. These differences can be resolved as follows:
- sets the topology comparison (p9906 or p9907/p9908).
- change over the actual topology.
The appropriate action should be selected corresponding to the message that is displayed/output.
Note:
In order to permanently accept the acknowledgement of the fault that can be resolved, then it must be saved in a
non-volatile fashion (p0977).
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
FFFF FFFF hex
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 hex
1-613

Hide quick links:

Advertisement

Table of Contents
loading