p4829
Function generator upper limit / FG upper limit
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
0.00 [%]
Description:
Sets the upper limit for the function generator.
Dependency:
For p4810 = 2 the limit only applies to the current setpoint, but not the speed setpoint (offset).
p4830
Function generator time slice cycle / FG time slice
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
0.03125 [ms]
Description:
Sets the time slice cycle in which the function generator is called.
p4831
Function generator amplitude scaling / FG amplitude scal
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
0.00000 [%]
Description:
Sets the scaling for the amplitude of the signal waveforms for all output channels.
The value can be changed while the function generator is running.
p4832[0...2]
Function generator amplitude scaling / FG amplitude scal
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
-340.28235E36 [%]
Description:
Sets the scaling for the amplitude of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
p4833[0...2]
Function generator offset scaling / FG offset scal
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
-340.28235E36 [%]
Description:
Sets the scaling for the offset of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
10000.00 [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
2.00000 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
200.00000 [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36 [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36 [%]
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
100.00 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0.12500 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
100.00000 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
100.00000 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
100.00000 [%]
1-475