Parameter
List of parameters
r0332[0...n]
Rated motor power factor / Mot cos_phi_rated
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: PEM, REL
Min
-
Description:
Displays the rated power factor for induction motors.
For IEC motors, the following applies (p0100 = 0):
For p0308 = 0, the internally-calculated power factor is displayed.
For p0308 > 0, this value is displayed.
For NEMA motors, the following applies (p0100 = 1):
For p0309 = 0, the internally-calculated power factor is displayed.
For p0309 > 0, this value is converted into the power factor and displayed.
Dependency:
If p0308 is not entered, the parameter is calculated from the rating plate parameters.
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
r0333[0...n]
Rated motor torque / Mot M_rated
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
- [Nm]
Description:
Displays the rated motor torque.
Dependency:
IEC drives (p0100 = 0): unit Nm
NEMA drives (p0100 = 1): unit lbf ft
Note:
For induction and reluctance motors, r0333 is calculated from p0307 and p0311.
For synchronous motors, r0333 is calculated from p0305, p0316, p0327 and p0328. The result can deviate from the
input in p0312. If p0316 = 0, then r0333 = p0312 is displayed.
In the case of multi-motor operation r0333 is increased by the factor p0306 compared to the rated torque of an indi-
vidual motor.
r0334[0...n]
Actual motor-torque constant / Mot kT act
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: ASM, REL, FEM
Min
- [Nm/A]
Description:
Displays the torque constant of the synchronous motor used.
Dependency:
IEC drives (p0100 = 0): unit Nm / A
NEMA drives (p0100 = 1): unit lbf ft / A
Refer to: p0316
Note:
This parameter is not used for induction motors (p0300 = 1xx).
For synchronous motors, parameter r0334 = p0316 is displayed. if p0316 = 0, r0334 is calculated from p0305 and
p0312.
1-84
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: MDS, p0130
Units group: 7_4
Scaling: -
Max
- [Nm]
Calculated: -
Dynamic index: MDS, p0130
Units group: 28_1
Scaling: -
Max
- [Nm/A]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: p0100
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: -
Unit selection: p0100
Expert list: 1
Factory setting
- [Nm/A]