p3233[0...n]
Torque actual value filter, time constant / M_act_filt T
SERVO_S110-CAN
Can be changed: U, T
(Ext msg),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Messages
(Ext msg),
Not for motor type: -
SERVO_S110-PN
(Ext msg)
Min
0 [ms]
Description:
Sets the time constant of the PT1 element to smooth the torque actual value.
The smoothed actual torque is compared with the threshold values and is only used for messages and signals.
p3235
Phase failure signal motor monitoring time / Ph_fail t_monit
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
0 [ms]
Description:
Sets the monitoring time for phase failure detection of the motor.
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
Note:
For p3235 = 0 the function is deactivated.
p3290
Variable signaling function start / Var sig start
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned8
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Settings for start/stop and the comparison type for the variable signaling function.
Bit field:
Bit
Signal name
00
Activate function
01
Comparison with sign
p3291
CI: Variable signaling function signal source / Var sig S_src
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned32 / Integer16
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the variable signaling function.
Dependency:
Refer to: p3292, p3293
Note:
Re p3291 = 1:
In this case, the signal source is defined using p3292 and p3293.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
1000000 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
2000 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Active
With sign
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: 8013
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
320 [ms]
Access level: 3
Func. diagram: 5301
Unit selection: -
Expert list: 1
Factory setting
0010 bin
0 signal
FP
Not active
-
Without sign
-
Access level: 3
Func. diagram: 5301
Unit selection: -
Expert list: 1
Factory setting
0
1-431