Siemens SINAMICS S110 List Manual page 127

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

r0499[0...2]
CO: Encoder diagnostic signal high word / Enc diag high word
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the trace signal for encoder diagnostics (high component).
The signal to be output is selected in p0496.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p0496, r0497, r0498
p0500
Technology application / Tec application
SERVO_S110-CAN,
Can be changed: C2(1, 5), T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Applications
Not for motor type: -
Min
100
Description:
Sets the technology application.
The parameter influences the calculation of open-loop and closed-loop control parameters that is e.g. initiated using
p0578.
Value:
100:
101:
102:
Dependency:
Refer to: p1520, p1521, p1530, p1531, p2000, p2175, p2177
Caution:
After changing over the technological application and then calculating the open-loop and closed-loop parameters,
the behavior of the motor can have changed very significantly (e.g. the same setpoint results in a higher speed due
to a different reference speed). For this reason extreme caution must be taken when the motor is started for the first
time.
Note:
The calculation of parameters dependent on the technology application can be called up as follows:
- when exiting quick commissioning using p3900 > 0
- when writing p0340 = 1, 3, 5
- when writing p0578 = 1
For p0500 = 100 and when the calculation is initiated, the following parameters are set:
- p1520/p1521 = rated motor torque (r0333)
- p1530/p1531= 2*pi*r0333*p0311 (rotary) or r0333*p0311 (linear)
- p2000 = rated motor speed (p0311)
- p2175 = factory setting
- p2177 = factory setting
For p0500 = 101 and when the calculation is initiated, the following parameters are set:
- p1520/p1521 = torque at the maximum motor current (p0323)
- p1530/p1531= power at the maximum motor current (p0323) and rated motor speed (p0311)
- p2000 = rated motor speed (p0311)
- p2175 = maximum value
- p2177 = 0.2 s
For p0500 = 102 and when the calculation is initiated, the following parameters are set:
- p1520/p1521 = rated motor torque (r0333)
- p1530/p1531= 2*pi*r0333*p0311 (rotary) or r0333*p0311 (linear)
- p2000 = maximum motor speed (p0322) if p0322 is not equal to 0, otherwise rated motor speed (p0311)
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Standard drive (SERVO)
Feed drive (limit current limitation)
Spindle drive (rated current limitation)
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
102
Parameter
List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100
1-127