Siemens SINAMICS S110 List Manual page 274

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r1939
Reluctance torque constant identified / kT_reluct ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [mH]
Description:
Displays the identified reluctance torque constant.
Dependency:
Refer to: r1937, r1938, p1959, p1960, r1969
Note:
This value corresponds to the reluctance torque constant (p0328).
r1947
Optimum load angle identified / phi_load ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [°]
Description:
Displays the identified, optimum load angle.
Note:
This value corresponds to the optimum load angle (p0327).
r1948
Magnetizing current identified / I_mag ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [Arms]
Description:
Displays the identified magnetizing current.
Dependency:
Refer to: r1936, p1959, p1960
Note:
This value corresponds to the magnetizing current (p0320 / r0331).
r1950[0...19]
Voltage emulation error voltage values / U_error U_values
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [V]
Description:
The identified characteristic of the voltage emulation error is displayed r1950[0...19] and r1951[0...19].
Dependency:
Refer to: r1951
r1951[0...19]
Voltage emulation error current values / U_error I_error
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [A]
Description:
The identified characteristic of the voltage emulation error is displayed r1950[0...19] and r1951[0...19].
Dependency:
Refer to: r1950
1-274
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [mH]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [°]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [Arms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [V]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [A]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [mH]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [°]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [Arms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [A]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents