Siemens SINAMICS S110 List Manual page 405

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p2658
BI: EPOS pos. actual value valid, feedback signal / Pos valid feedback
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the feedback signal "position actual value is valid".
BI: p2658 = 1 signal
The position actual value received via CI: p2657 is valid.
BI: p2658 = 0 signal
The position actual value received via CI: p2657 is invalid.
Dependency:
Refer to: r2526, p2657
Note:
While a 0 signal is present, the position setpoint (p2665) is held at the value of 0.
p2659
BI: EPOS referencing active feedback signal / Ref act fdbk
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the feedback signal "referencing active".
BI: p2659 = 1 signal
Referencing is active.
BI: p2659 = 0 signal
Referencing is not active.
Dependency:
Refer to: r2526
p2660
CI: EPOS measured value referencing / Meas val ref
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Integer32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the measured value for the function "referencing".
Dependency:
Refer to: r2523
p2661
BI: EPOS measured value valid, feedback signal / MeasVal valid fdbk
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
(EPOS),
P-Group: Basic positioner
SERVO_S110-PN
Not for motor type: -
(EPOS)
Min
-
Description:
Sets the signal source for the feedback signal "measured value valid".
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: 3635
Unit selection: -
Expert list: 1
Factory setting
2526.0
Access level: 3
Func. diagram: 3612
Unit selection: -
Expert list: 1
Factory setting
2526.1
Access level: 3
Func. diagram: 3612, 3614
Unit selection: -
Expert list: 1
Factory setting
2523[0]
Access level: 3
Func. diagram: 3612, 3614,
3615
Unit selection: -
Expert list: 1
Factory setting
2526.2
1-405

Hide quick links: