Siemens SINAMICS S110 List Manual page 721

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p20251
BI: PT1 1 accept setting value S / PT1 1 acc set val
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32 / Binary
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Sets the signal source for the "accept setting value" signal of instant PT1 1 of the smoothing element.
p20252
PT1 1 smoothing time constant in ms / PT1 1 T_smooth ms
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
0.00
Description:
Sets the smoothing time constant T in milliseconds of instance PT1 1 of the smoothing element.
r20253
CO: PT1 1 output Y / PT1 1 output Y
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Display parameter for the smoothed output quantity Y of instance PT1 1 of the smoothing element.
p20254
PT1 1 run-time group / PT1 1 RTG
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Integer16
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
0
Description:
Setting parameter for the run-time group in which instance PT1 1 of the smoothing element is to be called.
Value:
0:
1:
2:
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Run-time group 0
Run-time group 1
Run-time group 2
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
9999
Parameter
List of parameters
Access level: 1
Func. diagram: 7262
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 7262
Unit selection: -
Expert list: 1
Factory setting
0.00
Access level: 1
Func. diagram: 7262
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: 7262
Unit selection: -
Expert list: 1
Factory setting
9999